A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration. (c) 2008 Elsevier B.V. All rights reserved.
Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV
Martini M;
2009-01-01
Abstract
A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration. (c) 2008 Elsevier B.V. All rights reserved.File | Dimensione | Formato | |
---|---|---|---|
pub.pdf
non disponibili
Dimensione
116.73 kB
Formato
Adobe PDF
|
116.73 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |