In order to realize biomass potential as a major source of energy in the power generation and transport sectors, there is a need for high efficient and clean energy conversion devices, especially in the low-medium range suiting the disperseness of this fuel. Large installations, based on boiler coupled to steam turbine (or IGCC), are too complex at smaller scale, where biomass gasifiers coupled to ICEs have low electrical efficiency (15e30%) and generally not negligible emissions. This paper analyses new plants configurations consisted of Fast Internal Circulated Fluidized-Bed Gasifier, hot-gas conditioning and cleaning, high temperature fuel cells (MCFC), micro gas turbines,water gas shift reactor and PSAto improve flexibility and electric efficiency at medium scale. The power plant feasibility was analyzed by means of a steady state simulation realized through the process simulator Chemcad in which a detailed 2D Fortran model has been integrated for the MCFC. A comparison of the new plant working with external (MCFC-ER) and internal (MCFC-IR) reforming MCFC was carried out. The small amount of methane in the syngas obtained by atmospheric pressure biomass gasification is not enough to exploit internal reforming cooling in theMCFC. This issue has been solved by the use of prereformer working as methanizer upstream the MCFC. The results of the simulations shown that,when MCFC-IR is used, the parameters of the cell are bettermanaged. The result is a more efficient use of fuel even if someenergy has to be consumedin themethanizer. In the MCFC-IR and MCFC-ER configurations, the calculated cell efficiency is, respectively, 0.53 and 0.42; the electric power produced is, respectively, 236 and 216 kWe, and the maximum temperature reached in the cell layer is, respectively, 670°C and 700°C. The MCFC-ER configuration uses a cathode flowrate for MCFC cooling that are 30% lower than MCFC-IR configuration. This reduces pressure drop in the MCFC, possible crossover effect and auxiliaries power consumption. The electrical efficiency for the MCFC-IR configuration reaches 38%.

Comparison by the use of numerical simulation of a MCFC-IR and a MCFC-ER when used with syngas obtained by atmospheric pressure biomass gasification

Bocci E;
2011-01-01

Abstract

In order to realize biomass potential as a major source of energy in the power generation and transport sectors, there is a need for high efficient and clean energy conversion devices, especially in the low-medium range suiting the disperseness of this fuel. Large installations, based on boiler coupled to steam turbine (or IGCC), are too complex at smaller scale, where biomass gasifiers coupled to ICEs have low electrical efficiency (15e30%) and generally not negligible emissions. This paper analyses new plants configurations consisted of Fast Internal Circulated Fluidized-Bed Gasifier, hot-gas conditioning and cleaning, high temperature fuel cells (MCFC), micro gas turbines,water gas shift reactor and PSAto improve flexibility and electric efficiency at medium scale. The power plant feasibility was analyzed by means of a steady state simulation realized through the process simulator Chemcad in which a detailed 2D Fortran model has been integrated for the MCFC. A comparison of the new plant working with external (MCFC-ER) and internal (MCFC-IR) reforming MCFC was carried out. The small amount of methane in the syngas obtained by atmospheric pressure biomass gasification is not enough to exploit internal reforming cooling in theMCFC. This issue has been solved by the use of prereformer working as methanizer upstream the MCFC. The results of the simulations shown that,when MCFC-IR is used, the parameters of the cell are bettermanaged. The result is a more efficient use of fuel even if someenergy has to be consumedin themethanizer. In the MCFC-IR and MCFC-ER configurations, the calculated cell efficiency is, respectively, 0.53 and 0.42; the electric power produced is, respectively, 236 and 216 kWe, and the maximum temperature reached in the cell layer is, respectively, 670°C and 700°C. The MCFC-ER configuration uses a cathode flowrate for MCFC cooling that are 30% lower than MCFC-IR configuration. This reduces pressure drop in the MCFC, possible crossover effect and auxiliaries power consumption. The electrical efficiency for the MCFC-IR configuration reaches 38%.
2011
Power plant
reforming
fule cells
File in questo prodotto:
File Dimensione Formato  
Comparison-by-the-use-of-numerical-simulation-of-a-MCFC-IR-and-a-MCFC-ER-when-used-with-syngas-obtained-by-atmospheric-pressure-biomass-gasification_2011_International-Journal-of-Hydrogen-Energy.pdf

non disponibili

Dimensione 1 MB
Formato Adobe PDF
1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14241/4924
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
social impact