Today, in the grid there are more and more installation of renewable energy plants. The renewable sources are so discontinues and they may affect the stability and efficiency of the grid. Many distribution service operators are experimenting the battery energy storage systems (BESSs) to integrate them on the grid and resolve these problems. This paper analyses the energy performance under real conditions of a BESS prototype. The real BESS under focus has made by a lithium battery pack of 16 kWh, a DC/DC converter of 20 kW and an IGBT inverter of 30 kVA with a direct voltage bus of 600 V. The energy analysis has been performed through an integrated data acquisition system that take data from on-board electronic diagnostic measurements and from smart metering data. This latter using remote devices. The tests have been carried out on the system to monitor the following characteristic parameters: current and voltage of the batteries, current and voltage of the grid and current and voltage of the auxiliaries. The system energy performances have been analyzed in dynamic and real conditions with particular reference to the following quantities: energy consumption for the auxiliary system and overall efficiency of the system in a distributed energy resources microgrid. The entire system has been analyzed until twenty-four hours.

Energy Analysis of a Real Grid Connected Lithium Battery Energy Storage System

Bocci E
2015-01-01

Abstract

Today, in the grid there are more and more installation of renewable energy plants. The renewable sources are so discontinues and they may affect the stability and efficiency of the grid. Many distribution service operators are experimenting the battery energy storage systems (BESSs) to integrate them on the grid and resolve these problems. This paper analyses the energy performance under real conditions of a BESS prototype. The real BESS under focus has made by a lithium battery pack of 16 kWh, a DC/DC converter of 20 kW and an IGBT inverter of 30 kVA with a direct voltage bus of 600 V. The energy analysis has been performed through an integrated data acquisition system that take data from on-board electronic diagnostic measurements and from smart metering data. This latter using remote devices. The tests have been carried out on the system to monitor the following characteristic parameters: current and voltage of the batteries, current and voltage of the grid and current and voltage of the auxiliaries. The system energy performances have been analyzed in dynamic and real conditions with particular reference to the following quantities: energy consumption for the auxiliary system and overall efficiency of the system in a distributed energy resources microgrid. The entire system has been analyzed until twenty-four hours.
2015
Energy storage system
microgrid
lithium battery
energy performances
rlectrical fehicle
fast recharge
File in questo prodotto:
File Dimensione Formato  
Energy-Analysis-of-a-Real-Grid-Connected-Lithium-Battery-Energy-Storage-System_2015_Energy-Procedia.pdf

non disponibili

Dimensione 752.6 kB
Formato Adobe PDF
752.6 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14241/4949
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
social impact